Key Features
Rated Voltage
1000 Vdc
Rated Current (10 × 38 mm)
5–30 A
Rated Current (14 × 51 mm)
20–50 A
Rated Current (14 × 65 mm)
35–60 A
Rated Current (22 × 65 mm)
10–80 A
Maximum Breaking Capacity
30 kA @ 1000 Vdc
Max. BC (22 × 65 mm)
50 kA @ 1000 Vdc
Minimum Breaking Capacity
2In @ 1000 Vdc
Time Constant
2 ± 0.5 ms
Size
10 × 38, 14 × 51, 14 × 65, 22 × 65 mm
Manufacturer Information
Name of the manufacturer
-
Registered trade name / trademark
-
Postal address
Harmony Enclave, Bhosale Nagar, Shirgaon, Badlapur (E),
District Thane, Maharashtra – 421503, India.
Agency Information
-
Ref. to UL 248-20, ISO 8820-8, JASO D622, GB/T 31465.6
- Approval: TÜV and UL
- Manufactured under IATF 16949 quality system
- RoHS and REACH Compliant
Storage Information
During transportation and storage, avoid water seepage and
mechanical damage.
Operating Conditions
Where the following conditions apply, fuses complying with
this standard are deemed capable of operating satisfactorily
without further qualification.
-
Normal temperature: -5°C to 40°C; permissible operating
temperature: -40°C to 120°C.
-
Normal installation altitude does not exceed 2000 m;
permissible altitude does not exceed 5000 m.
-
The air is clean and its relative humidity does not exceed
50% at 40°C.
-
Higher relative humidity is permitted at lower
temperatures, e.g. 90% at 20°C.
- Pollution grade III.
-
Moderate condensation may occasionally occur due to
temperature variation.
-
For other operating conditions, please contact the
manufacturer.